| #24: Transient EMI Debug using Tektronix MDO4000 Mixed Domain Oscilloscope
Note that I revised this video recently. The revise video can be found here: • #76: Debug Transient EMI signal with ... This video shows an example of using the Tektronix MDO4000 Mixed Domain Oscilloscope to track down the source of a transient EMI problem on a circuit board. A near-field magnetic loop probe is used to scan the board for RF emission. The MDO is used to trigger on a transient RF source. The repetition rate of the RF burst is determined, and the source of the problem is located on the board.